Surgical gown fabric

  • Surgical gown fabric
  • Surgical gown fabric
  • Surgical gown fabric

Surgical gown fabric

Surgical gown fabric

Online Inquiry
Weight:45GSM
Specification:SMS Composite non-woven fabric
Width:160CM
General Craft:Spunbond + Meltblown + Spunbond
Features:Anti-penetration, abrasion resistance, anti-static, anti-tear

Functional use:

Used for medical surgical gown after sterilization The surgical gown plays a two-way protective role during the operation. First, the surgical gown establishes a barrier between the patient and the medical staff, reducing the probability of medical staff contacting the patient’s blood or other body fluids and other potential sources of infection during the operation; secondly, the surgical gown can block colonization/adhesion to the medical staff’s skin Or various bacteria on the surface of the clothes spread to the surgical patients, effectively avoiding cross-infection of multi-drug resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococcus (VRE). Therefore, the barrier function of surgical gowns is regarded as the key to reducing the risk of infection during surgery.

Product Details

产品详情
  • 01

    Breaking strength > 30N

    Good breaking strength can better protect medical staff and prevent the isolation suit from being damaged and infected
  • 02

    Hydrostatic pressure> 50CMH2O

    Allows medical staff to block the penetration of most droplets and liquids
  • 03

    Shock penetration<1 G

    Allows medical staff to block the penetration of most droplets and liquids
  • 04

    Burst strength > 40N

    Good bursting strength to avoid damage to the isolation garment due to pressure
  • 05

    Microbes CFU <100

    Dry resistance and microbial penetration test, aseptic growth
  • 06

    Fall< 4.0

    During the torsion and compression process, no flocculation is produced, to prevent the flocculation from infecting the patient during the rubbing of the garment
  • 07

    Antistatic

    Prevent static electricity in the operating room from causing large amounts of dust and bacteria to be absorbed by the surgical gown, which is not good for the patient’s wounds

Test Report

检测报告

EN 14126:2003

AAMI PB 70 level 4

SMMS AAMI PB 70 level 3

国标GTTC GB19082-2009

国标GB/T38642-2020

美标 ANSI/AAMI PB 70:2012 level 3

欧标:EN 13795-1:1019

国标CTI GB19082-2009

Online Inquiry